PVDF Tubing | Properties | Fluorotherm.com

Materials Overview

PVDF Properties

PVDF (KYNAR®) is generally used in applications requiring the high purity, strength, and resistance to solvents, acids, bases and heat. Compared to other fluoropolymers, like PTFEPFAFEP, it has an easier melt process because of its relatively low melting point of around 177°C.

KYNAR® is a registered trademark of Arkema, Inc

Maximum Usage Temperatures for PVDF

Lower Chain LengthImproved Flow
Strong Inter-chain ForcesHigher Modulus and Strength
Alternating C-H and C-F StructuresImproved Flammability

 

PVDF – Poly (vinylidene fluoride) - TYPICAL PROPERTIES
PropertyValueUnitsMethod
MECHANICAL PROPERTIES
Tensile Strength, 73°F, at break5075 - 7250
35 - 50
psi
MPa
D 638
Elongation at break, 73°F20 - 50%D 638
Flexural Strength, 73°F2100
11165
psi
MPa
D 790
Impact Strength, Izod, 23 deg C, notched, 4mm thick2.25
120
Ft-lbf/in
J/m
D 256
Yield StrengthAt 23 deg C7685 - 8265
53 - 57
psi
MPa
D 638
Density1.78gm/cu.cm
Coefficient of friction, static0.2 to 0.4D 1894
THERMAL PROPERTIES
Coefficient of Linear Expansion12 – 14 x 10-5K-1D 696
Melting Point343
173
deg F
deg C
D 3418
Thermal Conductivity1.39
0.2
Btu·in/h·ft2·°F
W/m·K
ASTM C 177
Specific Heat, at 300 deg K0.287 – 0.382
1.2 – 1.6
Btu/lb/deg F
kJ/Kg/deg K
Heat Distortion Temperature, 66 lb/sq.in (0.455 MPa), 4 mm thick293
145
deg F
deg C
D 648
Service Temperatureto 302
to 150
deg F
deg C
Processing Temperaturedeg F
deg C
ELECTRICAL PROPERTIES
Surface Arc-ResistancesecD 495
Volume Resistivity> 1014ohm-cmD 257/DIN 53483
Surface Resistivity, @ 100% RH> 1014Ohm sq-1D 257/DIN 53483
1MHz, 23 deg C7εD150-81
OTHER PROPERTIES
Flame Rating+V-0ClassUL-94
Refractive Index1.41 – 1.42nD 25D 542
Limiting Oxygen Index44% OxygenD 2863
Water Absorption, 230 deg C, 10 Kg< 0.04gm/10 minD 1238
Specific Gravity1.78ISO 1183

Value decreases with increasing thickness of test specimen

+ Numerical rating for flame spread is not intended to reflect hazards presented by this or any other material under actual fire conditions

NOTE: The information, recommendations and opinions contained herein is only a guide and is intended solely for your consideration, inquiry and verification. The suitability of any material under specific conditions of application is not guaranteed in any manner. Fluorotherm™ Polymers Inc does not assume legal responsibility for the use of data presented here in any form, under any circumstances, any application, test or communication. Nothing contained herein is to be interpreted as a license or authorization to operate under or infringe any patent.